current plans
updated8/19/06 tpe
- DC power upgrade, Power Supply is dieing! Need a replacement. Here
is the best option.
- control radio needs audio board built and tested
- Tower
- Super station master antenna is dead. Temp=regular station
master. Here is the best option, A
Super Station Master 220-2n (See celwave catalog
pages) Right now we are using a regular Station Master, no longer
made but the compatible part is the Station
Master II 200N. Quote from the spec sheets: "The 200n has been
specifically designed for simplex systems, dispatch and paging
applications in the 120-174 MHz frequency range."
- pvc
- jumpers
- 6mtrs SCOM 5k attachment
- 222 re-program.
- 449.425 heilacles,
- prep old 146.91 for re-use.
- 91 New Squelch mod
7/16/06 Power Supply measurements:
old supply 12V @ PA w/18watts RF out (12.4 @ supply)
(15amps calculated)
180watts DC to generate 18watts RF. Power conversion = 10:1
Good Supply:
13.93v @ Supply 24amps
13.3v @ PA w/39 watts out
(0.63v wire drop@ 24amps = 0.02625ohms loss)
319watts DC to generate 39watts RF. Power conversion = 8:1
The origional project has completed.